Scope of application
Widely used in cooling hydraulic systems and lubrication systems, especially in the fields of metal casting and forging, scrap recycling, and mining crushing. Oil chillers are highly matched with hydraulic power pack of shearing machines, bending machines, punching machines, hydraulic press, balers, shearing machines and other equipment, as well as lubrication power pack of crushers.
Characteristics
- High precision temperature control
- Rapid cooling without the influence of ambient temperature
- Cooling capacity: 1,500Kcal~250,000Kcal
- Two kinds of control methods: fixed temperature & room temperature synchronization
- High efficiency and cost-effective
Specification
Model |
ACO15PA |
ACO25PA |
ACO35PA |
ACO45PA |
ACO60PA |
ACO80PA |
ACO100PA |
ACO120PA |
ACO150PA |
ACO180PA |
|
Cooling capacity(Kcal/h) |
1500 |
2500 |
3500 |
4500 |
6000 |
8000 |
10000 |
12000 |
15000 |
18000 |
|
Temperature comtrol range |
28-45°C adjustable |
||||||||||
Input power(KW) |
1.2 |
1.7 |
2.1 |
2.6 |
3.5 |
4 |
5.6 |
6.5 |
7.8 |
9 |
|
Rated current |
6 |
8 |
10 |
12 |
8 |
10 |
14 |
16 |
18 |
20 |
|
Working condition |
Ambient temperature |
5- 43°C, well ventilated and non corrosive gas |
|||||||||
Oil temperature |
15-60°C |
||||||||||
Oil type |
Hydraulic oil,lubricating oil |
||||||||||
Oil viscosity |
10-100(viscosity values over 100 require customization) |
||||||||||
Power Supply |
3PH/AC380V±10%/50HZ |
||||||||||
Refrigerant |
Type |
R22/R407c/R410a |
|||||||||
Control method |
Electronic expansion valve |
||||||||||
Compressor |
Type |
Fully enclosed scroll compressor |
|||||||||
Input power(KW) |
0.68 |
0.88 |
1.2 |
1.73 |
2.2 |
2.58 |
3.58 |
4.4 |
5.2 |
5.8 |
|
Condenser |
Type |
high efficiency copper tube sleeve hydrophilic aluminum fin & external rotor axial fan |
|||||||||
Fan power(KW) |
0.08 |
0.1 |
0.135 |
0.185 |
0.23 |
0.25 |
0.45 |
0.55 |
0.8 |
0.85 |
|
Air flow(CBM/h) |
780 |
1580 |
2050 |
3950 |
4360 |
5420 |
7328 |
8560 |
11865 |
12480 |
|
Evaporator |
Type |
brazed plate heat exchanger |
|||||||||
Size of interface |
Type(internal thread) |
G1/2" × 1/2" |
G3/4" × 3/4" |
G3/4" × 3/4" |
G1" × 1" |
G1" × 1" |
G1/4" × 1" |
G1-1/4" × 1" |
G1-1/4"×G1-1/4" |
G1-1/4"×G1-1/4" |
G1-1/2"×G1-1/2" |
Power Supply |
Spec |
||||||||||
Pump(Optional variable frequency) |
Motor power(KW) |
0.375 |
0.375 |
0.375 |
0.375 |
0.375 |
1.1 |
1.1 |
1.5 |
1.5 |
2.2 |
Flow(L/min) |
8 |
16 |
16 |
24 |
32 |
40 |
50 |
63 |
63 |
80 |
|
Protective device |
high and low voltage protection, oil pump overload protection, power supply phase loss and reverse protection, compressor overheating production,abnormal alarm |
||||||||||
Remark: |
Model |
ACO200PA |
ACO240PA |
ACO300PA |
ACO350PA |
ACO400PA |
ACO500PA |
ACO600PA |
ACO800PA |
ACO900PA |
ACO1000PA |
|
Cooling capacity(Kcal/h) |
20000 |
24000 |
30000 |
35000 |
40000 |
50000 |
60000 |
80000 |
90000 |
100000 |
|
Temperature comtrol range |
28-45°C adjustable |
||||||||||
Input power(KW) |
11 |
12.5 |
15.5 |
17.5 |
21.5 |
27.5 |
30.5 |
39.5 |
47.5 |
53 |
|
Rated current |
24 |
28 |
32 |
32 |
48 |
55 |
65 |
75 |
82 |
90 |
|
Working condition |
Ambient temperature |
5- 43°C, well ventilated and non corrosive gas |
|||||||||
Oil temperature |
15-60°C |
||||||||||
Oil type |
Hydraulic oil,lubricating oil |
||||||||||
Oil viscosity |
10-100(viscosity values over 100 require customization) |
||||||||||
Power Supply |
3PH/AC380V±10%/50HZ |
||||||||||
Refrigerant |
Type |
R22/R407c/R410a |
|||||||||
Control method |
Electronic expansion valve |
||||||||||
Compressor |
Type |
Fully enclosed scroll compressor |
|||||||||
Input power(KW) |
7 |
4.4*4 |
5.2*2 |
5.8*2 |
14.2 |
9*2 |
10.3*2 |
14.2*2 |
5.3*6 |
16.9*2 |
|
Condenser |
Type |
high efficiency copper tube sleeve hydrophilic aluminum fin & external rotor axial fan |
|||||||||
Fan power(KW) |
0.85 |
0.55+0.45 |
0.8*2 |
0.85*2 |
0.85*2 |
0.95*2 |
1.1*2 |
1.5*2 |
2*2 |
2.2*2 |
|
Air flow(CBM/h) |
13010 |
15887 |
23730 |
24960 |
25380 |
31250 |
36000 |
12000 |
44000 |
48000 |
|
Evaporator |
Type |
brazed plate heat exchanger |
|||||||||
Size of interface |
Type(internal thread) |
G2" × 2" |
G2" × 2" |
G2" × 2" |
DN65*65 |
DN65*65 |
DN80*80 |
DN80*80 |
DN80*80 |
DN100*100 |
DN125*125 |
Power Supply |
Spec |
||||||||||
Pump(Optional variable frequency) |
Motor power(KW) |
2.2 |
2.2 |
3 |
4 |
5.5 |
7.5 |
7.5 |
7.5 |
11 |
11 |
Flow(L/min) |
100 |
100 |
125 |
160 |
200 |
250 |
250 |
350 |
400 |
500 |
|
Protective device |
high and low voltage protection, oil pump overload protection, power supply phase loss and reverse protection, compressor overheating production,abnormal alarm |
||||||||||
Remark: |
Model |
ACO1200PA |
ACO1600PA |
ACO2000PA |
ACO2500PA |
|
Cooling capacity(Kcal/h) |
120000 |
150000 |
200000 |
250000 |
|
Temperature comtrol range |
28-45°C adjustable |
||||
Input power(KW) |
60 |
79.5 |
99.8 |
115 |
|
Rated current |
118 |
158 |
200 |
232 |
|
Working condition |
Ambient temperature |
5- 43°C, well ventilated and non corrosive gas |
|||
Oil temperature |
15-60°C |
||||
Oil type |
Hydraulic oil,lubricating oil |
||||
Oil viscosity |
10-100(viscosity values over 100 require customization) |
||||
Power Supply |
3PH/AC380V±10%/50HZ |
||||
Refrigerant |
Type |
R22/R407c/R410a |
|||
Control method |
Electronic expansion valve |
||||
Compressor |
Type |
Fully enclosed scroll compressor |
|||
Input power(KW) |
21.2*2 |
14.2*4 |
18.4*4 |
21.2*4 |
|
Condenser |
Type |
high efficiency copper tube sleeve hydrophilic aluminum fin & external rotor axial fan |
|||
Fan power(KW) |
2.5*2 |
1.5*4 |
2.2*4 |
2.5*4 |
|
Air flow(CBM/h) |
53500 |
84000 |
96000 |
108000 |
|
Evaporator |
Type |
brazed plate heat exchanger |
|||
Size of interface |
Type(internal thread) |
DN125*125 |
DN150*150 |
DN150*150 |
DN200*200 |
Power Supply |
Spec |
||||
Pump(Optional variable frequency) |
Motor power(KW) |
11 |
15 |
18.5 |
18.5 |
Flow(L/min) |
500 |
700 |
1000 |
1200 |
|
Protective device |
high and low voltage protection, oil pump overload protection, power supply phase loss and reverse protection, compressor overheating production,abnormal alarm |
||||
Remark: |
Installation diagram