Leave Your Message

HITC series — variable frequency oil chiller

A variable frequency oil chiller is a precision temperature control device specifically designed for hydraulic oil systems or lubrication oil system. It uses variable frequency technology to precisely adjust the chiller's power. It effectively prevents thermal deformation and accuracy errors caused by excessively high oil temperatures. Compared to traditional fixed frequency oil chillers, TOBEL inverter oil chillers can save up to 25% on energy, and its temperature control accuracy is typically ±0.1 degrees Celsius.

    Characteristics

    • Efficient and energy-saving : saving 30% electricity compared to fixed frequency units
    • Accurate temperature control : The temperature of the chilled water is controlled within plus or minus 0.1 degrees , meeting the requirements of high - precision temperature control .
    • Rapid cooling : Compared to fixed frequency units , the cooling time is increased by 50%
    • Extend the lifespan of the compressor: the variable frequency host operates mostly under low - speed load , which has less wear on the compressor.
    • Low starting current : the starting current is small and has little interference with the power grid

    Specification

    Model

    HITC-O-80

    HITC-O-120

    HITC-O-200

    HITC-O-240

    HITC-O-300

    HITC-O-400

    HITC-O-500

    HITC-O-600

    HITC-O-800

    HITC-O-1000

    Cooling capacity(W)

    Low/High frequency

    2270/8170

    3043/12956

    5182/21653

    6751/24338

    8067/31068

    10365/41307

    13502/51676

    16134/62136

    20253/83014

    27010/102500

    Input Power(W)

    Low/High frequency

    1.31/4.15

    2.09/5.5

    3.67/8.98

    4.57/11.98

    5.01/14.75

    5.98/18.75

    8.06/22.42

    8.94/26.42

    12.29/33.23

    16.12/44.48

    Power Supply

    Variable frequency power supply

    Refrigerant

    Type

    R410a

    Control method

    Electronic expansion valve

    Compressor 

    Type

    fully enclosed scroll compressor

    Low frequency

    0.75

    0.96

    1.69

    2.15

    2.59

    3.38

    4.3

    5.18

    6.45

    8.6

    High frequency

    2.71

    3.46

    6.08

    7.74

    9.33

    12.15

    15.48

    18.66

    23.23

    30.96

    Condenser 

    Type

    high efficiency copper tube sleeve hydrophilic aluminum

    Fan power(KW)

    0.19

    0.38

    0.48

    0.92

    0.92

    1.1

    1.56

    1.56

    1.84

    2.25

    Flow(CBM/h)

    3000

    5000

    8000

    10000

    12000

    15000

    20000

    25000

    30000

    42500

    Evaporator

    type

    barzed plate heat exchanger

    Size of interface

    Type(SEA Flange)

    SEA 1" 

    SEA-1/2" 

    SEA1-1/2"

    SEA 2" 

    SEA 2" 

    SEA2-1/2" 

    SEA 3"

    SEA 3"

    SEA 4"

    SEA 4" 

    Power Supply

    Spec

    Pump(Optional variable frequency)

    Motor power(KW)

    1.1

    1.5

    2.2

    3

    3

    4

    5.5

    5.5

    7.5

    11

    Pipe size(inch)

    Flow(L/min)

    40

    63

    100

    100

    125

    200

    250

    250

    300

    400

    Refrigerant

     

    R140a

    Protective device

    high and low voltage protection, oil pump overload protection, power supply phase loss and reverse protection, compressor overheating production,abnormal alarm

    Remark:
    1. Above cooling capacity is measured under the conditions of oil temperature of 35℃ and ambient temperature of 35℃.
    2. When installing, a suction and exhaust space of not less than 300cm is required to be left around.
    3. Above are commonly used specifications and models,and can also be customized. Please contact us for details.

    Installation diagram

    tuoerpbr