Leave Your Message

UACW series — Low temperature water chiller

Industrial water chillers are divided into two types: air-cooled and water-cooled, mainly referring to the different condensers. Technically, water cooling is 300 to 500 kcal/h higher than air cooling; In terms of price, water cooling is much lower than air cooling; In the installation, water cooling needs to be incorporated into the cooling tower before use, and air cooling is mobile without other assistance. However, air cooled water chiller relies on the fan to dissipate heat, which has requirements for the ambient environment: such as ventilation, humidity, air PH value and etc...

    Scope of application

    Used for liquid rapid refrigeration, a wide range of petrochemical, medical, pharmaceutical, biochemical, freeze-drying, military and other high-tech industries

    Characteristic

    • Customized service, providing water chillers with temperature-35°C,-30°C,-20°C,-15°C or -10°C according to different working conditions
    • Adopting low temperature scroll compressor or piston compressor from well-known imported brand
    • All-closed system, no water absorption during low temperature operation to ensure the purity of the heat conducting medium and prevent ice crystals, thereby improving the service life of the thermal conductivity fluid

    Specification

    Type

    UACW-3L

    UACW-5L

    UACW-8L

    UACW-10L

    UACW-15L

    UACW-20L

    UACW-30L

    UACW-40L

    Temperature range

    -35°C,-30°C,-20°C,-15°C,-10°C

    Cooling capacity

     

    Kcal/h
    50/60Hz

    1462/1754

    1978/2374

    3956/4747

    5676/6811

    9718/11662

    11352/13622

    19436/23323

    22704/27245

    kW
    50/60Hz

    1.7/2.04

    2.3/2.76

    4.6/5.52

    6.6/7.92

    11.3/13.56

    13.2/15.84

    22.6/27.12

    26.4/31.68

    Input total power(kW)

    2.79

    3.63

    6.18

    8.82

    13

    17.36

    26.64

    34

    Power supply

    3Ø 380V/50Hz(customized)

    Refrigerant

    Type

    R404a(R507c)

    Control method

    Expansion valve

    Compressor

    Type

    Hermetically sealed compressor or piston compressor

    Power(kW)

    1.85

    2.5

    4.95

    6.8

    10.4

    13.6

    20.8

    27.2

    Condenser

    Type

    Efficient copper tube cover aluminium & low noise external rotor fan

    Fan power(kW)

    0.19

    0.38

    0.48

    0.92

    1.1

    1.56

    1.84

    2.8

    Evaporator

     

    Type

    Shell & tube plate heat exchanger

    Chilled water flow(m3)

    0.82

    1.11

    2.22

    3.19

    5.46

    6.38

    10.92

    12.76

    Inlet & outlet pipe diameter

    1''

    1''

    1-1/2''

    1-1/2''

    2''

    2''

    2-1/2''

    2-1/2''

    Water pump

    Power(kW)

    0.75

    0.75

    0.75

    1.1

    1.5

    2.2

    4

    4

    Lift(m)

    18

    18

    18

    20

    20

    20

    25

    20

    Safety protection

    compressor overheating protection,over current protection,high and low pressure protection,phase sequence protection,high exhaust heat protection,frost protection

    Machine weight(kg)

    135

    175

    310

    450

    750

    835

    1080

    1125

    Remark:

    1.The cooling capacity is based on the inlet water temperature of 7°C and outlet water temperature of 12°C, and ambient temperature is 30°C/35°C.

    2.Working condition: Chilled water temperature range is from 5°C to 35°C; the difference between the inlet and outlet of chilled water temperature is from 3°C to 8°C, and ambient temperature is lower than 35°C.

    3.Contact us for customized solutions.