WCW series — Water cooled box type water chiller

Industrial water chillers are divided into two types: air-cooled and water-cooled, mainly referring to the different condensers. Technically, water cooling is 300 to 500 kcal/h higher than air cooling; In terms of price, water cooling is much lower than air cooling; In the installation, water cooling needs to be incorporated into the cooling tower before use, and air cooling is mobile without other assistance. However, air cooled water chiller relies on the fan to dissipate heat, which has requirements for the ambient environment: such as ventilation, humidity, air PH value and etc...

    Scope of application

    Water cooled box type chiller is a kind of refrigeration equipment which uses external cooling water source instead of fan to force heat transfer into the air. The energy efficiency ratio will be higher than air-cooled chiller. Usually water cooled chiller is used for the occasions with large cooling capacity, dust and high ambient temperature.

    Configurable options

    • Salt water evaporator
    • Special requirement of power supply
    • Remote communication connector

    Characteristics

    • The water chiller has compact structure, small footprint and simple pipeline design, only needs to connect external water pipe. 
    • Easy installation and maintenance. 
    • With intelligent control, the chiller can automatically adjust the output of the compressor according to the load change, so that the chiller has the best work efficiency at any time.
    • Fully sealed compressor with superior performance and strong resistance to liquid shock
    • Man-machine interface: the chiller adopts well-known brand controller and control interface, digital display, one-click operation
    • Water pump tank: The unit adopts the overall design and manufacture, built-in standard efficient centrifugal pipeline pump, 304 stainless steel cold storage tank.
    • Environmentally friendly refrigerant is available,such as R407c, R134a or R410a and so on.

    Specification

    Type

    WCW-3.1

    WCW-5.1

    WCW-8.1

    WCW-10.1

    WCW-12.1

    WCW-15.1

    WCW-20.2

    WCW-25.2

    WCW-30.2

    WCW-40.2

    WCW-50.4

    WCW-60.4

    Nominal cooling capacity(103Kcal/h)

    7.6

    12.4

    21.9

    25

    28.1

    35.4

    49.9

    56.3

    70.7

    95.2

    112.6

    141.5

    Rated power(kW)

    3.4

    5.1

    8

    9.3

    10.4

    14.1

    18

    20.5

    28.6

    37

    44.3

    61.9

    Rated current(A)

    6.1

    9.3

    14.7

    16.9

    19

    25.8

    32.9

    37.5

    52.3

    67.7

    81.1

    113.3

    Compressor

    Refrigeration power(kW)

    2.6

    4.3

    7

    7.9

    8.9

    12.4

    15.7

    17.9

    24.9

    33.3

    35.76

    49.76

    Refrigeration current(A)

    4.6

    7.6

    12.4

    14

    15.9

    22.1

    28

    31.8

    44.3

    59.2

    63.7

    88.6

    Quantity

    1

    1

    1

    1

    1

    1

    2

    2

    2

    2

    4

    4

    Condenser fan

    Single fan power(kW)

    0.24

    0.24

    0.3

    0.3

    0.32

    0.55

    0.75

    1.1

    1.5

    0.75

    0.75

    1.1

    Single station current(A)

    0.48

    0.48

    0.6

    0.6

    0.67

    1.42

    1.94

    2.4

    4.5

    1.94

    1.94

    2.8

    Quantity

    2

    2

    2

    2

    2

    2

    2

    2

    2

    6

    6

    6

    Chilled water

    Flow(L/min)

    25

    41

    73

    83

    83

    118

    166

    187

    235

    316

    374

    470

    Connection(mm)

    R1

    R1

    R1-1/4

    R1-1/4

    R1-1/4

    R1-1/2

    R1-1/2

    R2

    R2

    R2-1/2

    R2-1/2

    DN80

    Lift(mH2O)

    16

    21

    22

    19

    17

    25

    24

    23

    22

    30

    31

    30

    Tank volume(L)

    75

    75

    100

    140

    195

    205

    245

    270

    360

    400

    455

    500

    Machine weight(kg)

    150

    200

    285

    350

    450

    600

    830

    83

    1050

    1250

    1450

    1560

    Technical note:

    1.Refrigeration condition: water inlet temperature 12°C and water outlet temperature 7°C, ambient temperature 35°C.

    2.Safety scope of work: inlet temperature of chilled water is 9~20°C。

    3.Power supply: 3Ø 380V/50Hz(customized). Three-phase four-system is recommended, voltage fluctuation ±5%,frequency fluctuation ±2%.

    4.Contact us for customized solutions.