WSCW series — Water cooled screw type water chiller
Characteristics
- World-renowned twin-screw compressor, high efficiency, low noise, less wearing and long service life
- SIEMENS PLC controller with Chinese/English human-computer interface
- Electrical system uses Schneider and other national brands
- Man-machine interface: the chiller adopts well-known brand controller and control interface, digital display, one-click operation
- Perfect breakdown protection:high and low pressure protection, anti-freezing protection, water flow protection, reverse and lack phase protection
- Ultra-wide variable range of chilled water temperature
Configurable options
- Salt water evaporator
- Stepless energy adjustment
- Heat recovery
- Pump control
- Special requirement of power supply
- LoT monitoring
Specification
SINGLE COMPRESSOR
Type |
WSCW-100.1 |
WSCW-135.1 |
WSCW-180.1 |
WSCW-195.1 |
WSCW-235.1 |
WSCW-260.1 |
WSCW-305.1 |
WSCW-320.1 |
WSCW-350.1 |
WSCW-385.1 |
|
Nominal cooling capacity |
kW |
100 |
135 |
180 |
195 |
235 |
260 |
305 |
320 |
350 |
385 |
|
(104Kcal/h) |
8.6 |
11.6 |
15.5 |
16.8 |
20.3 |
22.4 |
26.3 |
27.6 |
30.2 |
33.2 |
Controller |
PLC microcomputer control |
||||||||||
Power supply |
3Ø 380V/50Hz(customized) |
||||||||||
Compressor |
Type |
5-6 asymmetric semi-closed twin-screw compressor |
|||||||||
Start-up mode |
star-delta starting |
||||||||||
Energy regulation |
0-33-66-100% |
0-25-50-75-100% |
|||||||||
Refrigeration power(kW) |
22.6 |
29.8 |
37.3 |
41 |
49.9 |
54.3 |
61.1 |
64.3 |
70.8 |
78 |
|
Rated current(A) |
39.3 |
51.9 |
64.9 |
71.3 |
86.8 |
94.5 |
106.3 |
111.9 |
123.2 |
135.7 |
|
Evaporator |
Type |
shell-tube dry evaporator |
|||||||||
Flow(m3/h) |
17.2 |
23.2 |
31 |
336.6 |
40.6 |
44.8 |
52.6 |
55.2 |
60.4 |
66.4 |
|
Connection(Inch) |
DN65 |
DN80 |
DN100 |
DN125 |
|||||||
Water pressure drop(kPa) |
48 |
48 |
50 |
50 |
50 |
52 |
54 |
55 |
55 |
58 |
|
Condenser |
Type |
shell-tube dry evaporator |
|||||||||
Flow(m3/h) |
21.5 |
29 |
38.7 |
41.9 |
50.5 |
55.9 |
65.6 |
68.8 |
55 |
58 |
|
Connection(Inch) |
DN65 |
DN80 |
DN100 |
DN125 |
|||||||
Water pressure drop(kPa) |
46 |
46 |
47 |
47 |
48 |
49 |
51 |
53 |
75.3 |
82.8 |
|
Refrigerant |
Type |
R22(optional) |
|||||||||
Refrigerant charge(kg) |
20 |
25 |
30 |
40 |
45 |
49 |
51 |
53 |
53 |
56 |
|
Machine weight(kg) |
850 |
1050 |
1270 |
1340 |
1640 |
1680 |
1720 |
1750 |
2080 |
2300 |
|
Operating weight(kg) |
900 |
1150 |
1420 |
1540 |
1890 |
1940 |
1990 |
2050 |
2330 |
2550 |
|
Technical note: | |||||||||||
1.Condition: chilled water inlet temperature 12°C and outlet temperature 7°C, cooling water inlet temperature 30°C and outlet temperature 35°C. | |||||||||||
2.Temperature condition:chilled water outlet temperature 5°C-15°C; and cooling water inlet temperature 19°C-33°C. | |||||||||||
3.The water side pressure of evaporator and condenser is designed to be 1.0MPa. | |||||||||||
4.The water-side fouling factor of evaporator is 0.018m2 °C/kW, water-side fouling factor of condenser is 0.044m2 °C/kW. | |||||||||||
5.Contact us for customized solutions. |
DUAL COMPRESSOR
Type |
WSCW-200.2 |
WSCW-270.2 |
WSCW-360.2 |
WSCW-390.2 |
WSCW-470.2 |
WSCW-520.2 |
WSCW-610.2 |
WSCW-640.2 |
700.2 |
WSCW-770.2 |
|
Nominal cooling capacity |
kW |
200 |
270 |
360 |
390 |
470 |
520 |
610 |
640 |
700 |
770 |
|
(104Kcal/h) |
17.2 |
23.3 |
31 |
34 |
40.5 |
44.8 |
52.6 |
55.2 |
60 |
66 |
Controller |
PLC microcomputer control |
||||||||||
Power supply |
3Ø 380V/50Hz(customized) |
||||||||||
Compressor |
Type |
5-6 asymmetric semi-closed twin-screw compressor |
|||||||||
Start-up mode |
star-delta starting |
||||||||||
Energy regulation |
0-16.5-33-50-66-83.5-100% |
0-12.5-25-37.5-50-62.5-75-87.5-100% |
|||||||||
Refrigeration power(kW) |
45.2 |
60 |
75 |
82 |
99.8 |
108.6 |
122.2 |
128.6 |
141.6 |
156 |
|
Rated current(A) |
78.6 |
103.7 |
129.8 |
142.7 |
173.7 |
189 |
212.6 |
223.8 |
246.4 |
271.4 |
|
Evaporator |
Type |
shell-tube dry evaporator |
|||||||||
Flow(m3/h) |
34.4 |
46.6 |
62 |
68 |
81 |
89.6 |
105.2 |
110.4 |
120 |
132 |
|
Connection(Inch) |
DN80 |
DN100 |
DN125 |
DN150 |
|||||||
Water pressure drop(kPa) |
50 |
52 |
52 |
53 |
54 |
55 |
55 |
55 |
60 |
68 |
|
Condenser |
Type |
shell-tube dry evaporator |
|||||||||
Flow(m3/h) |
43 |
58.1 |
77.4 |
83.9 |
101.1 |
111.8 |
131.2 |
137.6 |
150.5 |
165.6 |
|
Connection(Inch) |
DN65*2 |
DN80*2 |
DN100*2 |
DN125*2 |
|||||||
Water pressure drop(kPa) |
45 |
45 |
45 |
47 |
50 |
52 |
53 |
55 |
58 |
60 |
|
Refrigerant |
Type |
R22 |
|||||||||
Refrigerant charge(kg) |
40 |
50 |
60 |
80 |
90 |
95 |
100 |
110 |
130 |
150 |
|
Machine weight(kg) |
1650 |
1850 |
2300 |
2400 |
2800 |
3000 |
3100 |
3200 |
4000 |
4500 |
|
Operating weight(kg) |
1900 |
2150 |
2550 |
2750 |
3350 |
2550 |
3600 |
3750 |
4450 |
4950 |
|
Technical note: | |||||||||||
1.Condition: chilled water inlet temperature 12°C and outlet temperature 7°C, cooling water inlet temperature 30°C and outlet temperature 35°C. | |||||||||||
2.Temperature condition:chilled water outlet temperature 5°C-15°C; and cooling water inlet temperature 19°C-33°C. | |||||||||||
3.The water side pressure of evaporator and condenser is designed to be 1.0MPa. | |||||||||||
4.The water-side fouling factor of evaporator is 0.018m2 °C/kW, water-side fouling factor of condenser is 0.044m2 °C/kW. | |||||||||||
5.Contact us for customized solutions. |